ENKA-OGRZEWANIE




ENKA SET 2

-->
PDF INSTUCTION
PDF INSTUCTION ECOMAX 800W
PDF DTR PALNIKA



MULTI-FUEL ENKA SET 2 CH BOILERS
FUEL - [ eco-bean ]

SET 2 Type screw conveyor Boilers are designed for burning eko-bean type of fuel, including coal and timber, in an alternative combustion chamber. Eco-bean enables the best burning parameters in respect of pure fumes and minimum ashes. Up to 90% efficiency, several days basket capacity, the highest construction material quality make ENKA SET 2 Boilers comfortable, cheap and environment friendly source of heat. Available are 12 to 150KW ranges of power. The Boilers are designed for operation in an open type of installations with an option of appliance in closed type of systems. ENKA SET 2 Boilers are made of 6 to 8 mm boiler steel making the water insert, profiled and bent in 70%, with no welding used. Temperature exposed elements: boiler door, wash-hole covers and door elements are made of cast-iron and coated with thermal paint and insulated with ceramics. The Boiler enables high efficiency and access to service parts, and servicing EKO MAX 800 enables capabilities of control in the environment of different combinations of floor heating, HHW and CH. In front of the Boiler, the upper door are used to clean the condensation section, with central door for traditional type of burning (when placing cast-iron grate), while the bottom door is used for igniting the fuel delivered by conveyor, and bottom door (ashes) including the tray for ash removal. The fuel is delivered from fuel basket by screw conveyor. Fuel is burned in cast-iron fixed combustion chamber.
SET 2 Model is normally equipped with weather sensor and all sensors required by any type of installations.



ENKA SET 2

Measurement unit

12KW

15KW 18KW 22KW 26KW

36KW

RANGE OF POWER

KW

5-14

5-16 10-22 15-26 20-32

28-42

LIVING SPACE SERVED

m

do 80

do 100
do 170
do 220
do 260

do 380

SINGLE FUEL BATCH

kg

160

160
160
160
180

250

MAX. HEATATING EFFICIENCY

%

86

86
86
92
92

92

OPERATIONAL PRESSURE

Mpa

0,10 lub 0,25(opcja)

REQUIRED CHIMNEY DRAW

Pa

22

22
24
27
28

32

BOILER WEIGHT

kg

300

340
380
450
520

620

WATER VOLUME

L

38

48
60
78
90

150

REQUIRED CHIMNEY DIAMETER

160

160
160
180
180

200

MIN. HEIGHT OF CHIMNEY

m

6

7
7
8
8

8

BOILER WIDTH

cm

108

108
108
112
112

125

BOILER DEPTH

cm

67

67
67
67
67

70

BOILER HEIGHT

cm

115

125
140
150
162

155

RETURN CIRCULATION DIAMETER

cal

11/4

FLUE DIAMETER

cm

130

160
180
180
180

180

FLUE HEIGHT IN BOILER

FROM THE FLOOR TO OUTLET CENTRE

cm

107

117
127
137
143

143